GGD AC LOW-VOLTAGE DISTRIBUTION CABINET

GGD AC LOW-VOLTAGE DISTRIBUTION CABINET

GGD AC low voltage distribution cabinet is used for power users such as power plants, substations, factories, and mining enterprises. It serves as an AC 50-60Hz distribution system with a rated working voltage of 380V and a rated working current up to 3150A. It is used for power conversion, distribution, and control of power, lighting, and distribution equipment.

The GGD type AC low-voltage distribution cabinet is a new type of low-voltage distribution cabinet designed based on the requirements of the Ministry of Energy’s power users and design departments, following the principles of safety, economy, rationality, and reliability. The product has the characteristics of high breaking capacity, good dynamic and thermal stability, flexible electrical scheme, convenient combination, strong series and practicality, novel structure, and high protection level. Can be used as a replacement product for low-voltage switchgear.

The GGD type AC low-voltage distribution cabinet complies with national and industry standards.

GGD AC LOW-VOLTAGE DISTRIBUTION CABINET

LOW LOSS

HIGH ENERGY EFFICIENCY

WIDELY APPLICABLE

SEALED OIL TANK

Applicable Scenarios

  • The ambient air temperature shall not exceed+40 ℃ and not be lower than -5 ℃, and the average temperature within 24 hours shall not exceed+35 ℃.
  • For indoor installation and use, the altitude of the usage location shall not exceed 2000m.
  • The relative humidity of the surrounding air should not exceed 50 ℃ at a maximum temperature of+40 ℃, and a higher relative humidity is allowed at lower temperatures, such as 90% at+20 ℃. It should be considered that condensation may occur accidentally due to temperature changes.
  • Pollution level 3.
  • The inclination of the equipment during installation with respect to the vertical plane shall not exceed 5 °.
  • The equipment should be installed in places without severe vibration and impact, as well as in places where electrical components are not corroded.

Core Parameters

ProjectUnitParameters
Rated voltageVAC380
Rated frequencyHZ50
Rated currentMaximum working current of horizontal busbarA≤ 4000
Maximum working current of vertical busbar800、1600
Rated short-time withstand current (1s)kA15、30、50
Rated peak withstand currentkA30、63、105
Dielectric strengthV/1min2500
Rated insulation voltageV660
Protection gradeIP30/IP40
Dimensions (width x depth x height)mm600(800、1000)×600(800、1000)×2200

Competitive Comparison

FeatureGGD AC LOW-VOLTAGE DISTRIBUTION CABINETConventional Similar Transformer
No-load lossLower (energy-saving series)Higher standard series
Partial dischargeLow partial discharge, high reliabilityStandard level
MaintenanceMaintenance-free, low operational costPeriodic maintenance required
Fire safetyFlame retardant & explosion-proofVaries

Application Areas

transportation

industry

Urban Community

agriculture

Frequently Asked Questions

What is the rated capacity of GGD AC LOW-VOLTAGE DISTRIBUTION CABINET?

The GGD AC LOW-VOLTAGE DISTRIBUTION CABINET is available in a range of rated power options; the exact kVA for your application is listed in the Core Parameters table.

What are the main advantages of GGD AC LOW-VOLTAGE DISTRIBUTION CABINET?

Low loss and high energy efficiency, low partial discharge, high mechanical strength, short-circuit and lightning resistance, flame retardant, maintenance-free and compact footprint.

What are the applicable scenarios for GGD AC LOW-VOLTAGE DISTRIBUTION CABINET?

It is suitable for medium and high voltage power transmission and distribution projects, urban communities, industry, transportation and agriculture, meeting continuous operation under conventional and harsh conditions.

Does GGD AC LOW-VOLTAGE DISTRIBUTION CABINET require special installation?

No oil discharge tank, fire-fighting or backup power facilities are needed, so it can be installed fully close to the power point with low installation cost.